G Grizzly Backflow & Plumbing
New River, VA · 24129 Local testers · Utility reports filed

PVB Testing in New River, VA Near Me

PVB (pressure vacuum breaker) testing in New River, VA for lawn sprinklers and irrigation lines. Call (833) 990-5874.

PVB Testing in New River, VA
Call us
(833) 990-5874
Certified testers
Reports filed with your utility
RPZ, DCVA and PVB
Price talked through by phone

PVB Testing in New River, VA

The pressure vacuum breaker, or PVB, is the brass device sticking out of the ground near your sprinkler system with a bonnet on top and two small test cocks. It is the most common backflow preventer on residential irrigation.

A PVB test checks two things. The air inlet has to open when pressure in the body drops to about 1.0 psi. The check valve has to hold at least 1.0 psid in the direction of flow.

The usual failures are a cracked bonnet from a freeze, a stuck poppet, or a check that leaks because the rubber has gone hard after years in the sun. Water spitting out from under the canopy when the system starts is a sign the poppet is not seating.

A PVB must sit at least 12 inches above the highest sprinkler head it serves. If yours is lower, it may not pass inspection even with good readings.

Grizzly Backflow & Plumbing connects New River, VA homeowners with testers for PVB testing and backflow prevention repairs. Call (833) 990-5874.

How it works

Four steps to backflow testing in New River, VA

  1. 01

    Grab your notice

    Have the utility letter handy. It lists the device, serial number and due date.

  2. 02

    Talk it through

    Call (833) 990-5874. We go over the device type and the price before anything is booked.

  3. 03

    Test day

    A certified tester reads each check and the relief valve on a calibrated gauge.

  4. 04

    Report filed

    The report goes to your water utility, and you keep a copy for your records.

Coverage

Backflow Testing Services Across New River, VA

Backflow testing for the neighborhoods and ZIP codes around New River, VA.

ZIP codes we serve

24129

Backflow testing FAQs

Questions about backflow testing

Questions we hear most often about PVB Testing in New River, VA.

Talk to a person
How often does a backflow preventer need testing in New River, VA?
Most water utilities require a test once a year. Many also require one at installation, after any repair and after the device is moved. Your utility's notice letter gives the exact due date.
Will my water be off during the test?
Yes, briefly. The tester closes the shutoff valves on the assembly while reading the checks, so water downstream of the device is off until the test is done.
What does a failed backflow test mean?
A check valve or the relief valve did not hold its required pressure differential. The device needs repair or replacement, then a retest before a passing report can be filed.
Do I need an expansion tank after installing a backflow preventer?
Often, yes. The device makes your plumbing a closed system, so heated water cannot expand back to the main and the water heater relief valve may start dripping.
What is a cross-connection?
Any point where drinking water piping can come into contact with a non-potable source. Common examples are a hose in a bucket, a boiler fill line and an irrigation system.

Book a backflow test

Backflow Test Due in New River, VA? Call now.

Certified testers for backflow testing in New River, VA. Call (833) 990-5874 and we go through the device and the price before anything is booked.

(833) 990-5874
Phone · (833) 990-5874
Call (833) 990-5874 Enquire